Deformation Simulation Laboratory (Gleeble 3800 Thermomechanical Simulator + Dilatometer DIL 805 AD)
Equipment Code : 2745788
Make : Dynamic Systems Inc. DSI, USA and TA Instruments Germany
Model : Gleeble 3800 system and DIL805A/D
Institution : Indian Institute of Technology (IIT) Bombay
Department : Centre for Sophisticated Instruments and Facilities
Funding Agency Details :
Pooling of Equipment slot : No
Last AMC Done :
Reference Website : https://instruments.iitb.ac.in/deformation-simulation-laboratory
Description : 1. Dynamic Systems Inc. (DSI), Gleeble 3800 system, USASpecification/Features:Controlled deformation at different heating (10,0000C/s) and cooling (~6500C/s)Physical simulations for all fabrication and thermo-mechanical processing.Strain rate: 10^-3 to 100Atmosphere: Vacuum, Ambient air, Argon, Nitrogen Cooling conditions: Water Quenching, Forced Air Cooling, Coolinghttps://gleeble.com/products/gleeble-systems/gleeble-3800.html2. TA Instruments-DIL 805A/D, GermanySpecification/Features:Accurate (0.05 ?m & 0.05 0C) identification of all transformationsControlled simulations for investigation of microstructural evolutionStrain rate: 10^-3 to 10^-1Atmosphere: Vacuum, Ambient air, Argon, Nitrogen, Helium Cooling conditions:Gas cooling Coolinghttps://www.tainstruments.com/dil-805ad/
| Samples | External Academic User | Internal Academic User | Industry User | Start-ups |
|---|---|---|---|---|
|
(Gleeble-3800) Flow Stress/Plane Strain Test with air cooling/normal cooling Temperature below 1200 Degree Celsius
|
|
|
|
|
|
(Gleeble-3800) Flow Stress / Plane Strain Test with water quenching Temperature below 1200 Degree Celsius
|
|
|
|
|
|
(Gleeble-3800) Tensile Test Temperature below 1200 Degree Celsius with air cooling/normal cooling
|
|
|
|
|
|
(DIL805A/D) Quenching using Ar/N2/He for 2 hours upto Temperature 1400 Degree Celsius
|
|
|
|
|
|
(DIL805A/D) Deformation Low Strength Alloy Temperature upto 1400 Degree Celsius
|
|
|
|
|
|
(DIL805A/D) Sub-Zero Test (in multiples of 6 hrs)
|
|
|
|
|
|
(DIL805A/D) Alpha-measurement (in multiples of 6 hrs)
|
|
|
|
|
|
(DIL805A/D) Deformation: High Strength alloy
|
|
|
|
|
|
(Gleeble-3800) Tensile Test with water quenching below 1200 Degree Celsius
|
|
|
|
|
|
(Gleeble-3800) Flow Stress/Plane Strain Test with air cooling/normal cooling Temperature above 1200 Degree Celsius
|
|
|
|
|
|
(Gleeble-3800) Flow Stress / Plane Strain Test with water quenching Temperature above 1200 Degree Celsius
|
|
|
|
|
|
(Gleeble-3800) Diffusion Bonding Upto 2 hrs
|
|
|
|
|
| Sample Name | Sample Type | Sample UOM | Sample Availability | Unit Cost | Sample Quantity | Sample Description |
|---|---|---|---|---|---|---|